Call 07942556559 87% Response Rate

Send Enquiry

our range

New Items

Fibrovein Injection Sodium Tetradecyl Sulfate Inj

  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
  • Fibrovein Injection Sodium Tetradecyl Sulfate Inj
Fibrovein Injection Sodium Tetradecyl Sulfate Inj
Get Best Quote
Rs 2,500  / VialPrice on Request

Minimum Order Quantity: 5 Vial

Product Brochure

Strength1 mg/ml
Vial Size5 ml
BrandSTD Pharma
IndicationVaricose Veins, Vascular Sclerotherapy, Hemorrhoids
FormVial
Pack TypeBox of 5
RouteIntravaricose
Storage TempBelow 25 deg C
PrescriptionPrescription Only
Considerations for successful Foam Sclerotherapy
1 Pre-operative duplex ultrasound examination of the leg is mandatory
2 Use Terumo syringes and Vygon 3-way tap with Luer Lock connections to make stable foam using the Tessari technique
3 Use one part liquid sclerosant to three or four parts of air
4 Prepare foam immediately before use
5 Administer foam in no greater than 2ml aliquots approximately 10-15 cm apart in the truncal veins and use a maximum of 16ml of foam per patient per 24hours
6 Empty the vein of blood as much as possible before foam injection, for example by raising the leg in the air or flushing with saline
7 Use 3% Fibrovein foam in truncal veins below the fascia and use 1% Fibrovein foam in more superficial veins
8 Remember sodium tetradecyl sulfate is at least twice as potent as polidocanol
9 Apply eccentric compression following foam sclerotherapy 10 Encourage patients to walk frequently after foam sclerotherapy


Considerations for successful Microsclerotherapy
1 Perform an ultrasound examination of the limb to exclude underlying venous insufficiency
2 Use liquid sclerosant—there is no benefit to using foam in small diameter veins
3 Use 0.5% Fibrovein for treating reticular veins and 0.2% Fibrovein for treating spider veins
4 Consider further dilution of 0.2% Fibrovein to 0.1% with normal saline for very fine diameter veins1,2
5 Use fine gauge needles typically 30G
6 Treat an area of no greater than 2 cm diameter with each injection
7 Inject no more than 0.1– 0.2ml volume with each injection
8 Use a maximum of 10ml 0.2% or 0.5% per patient per 24hours
9 Remember sodium tetradecyl sulfate is at least twice as potent as polidocanol, so use 0.2% for spider veins 10 Apply concentric compression followin

Additional Information:

  • Item Code: LS024
  • Production Capacity: 20 per week
  • Delivery Time: 2 days
  • Packaging Details: Pack of 5 vials in 1 box

View Complete details

Yes! I am Interested Request a call back

Surgical Knot pusher

  • Surgical Knot pusher
  • Surgical Knot pusher
  • Surgical Knot pusher
Surgical Knot pusher
Get Best Quote
Rs 1,300  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Knot TypeOpen Surgery
Tip ShapeOpen Slot
Diameter3 mm
Length150mm
Suture SizeUp To 1 0
Handle TypeRod Handle
Usage/ApplicationHospital
Disposable/ ReusableReusable
Usage TypeReusable
MaterialStainless Steel
SterilityPre Sterile
A General  knot pusher is an essential surgical instrument used in minimally invasive procedures to assist surgeons in securely tying and tightening sutures inside the patient's body (intracorporeal knot tying) or for pushing pre-tied knots down to the tissue (extracorporeal knot tying). Total length 18.5cm & Handle to end 14cm

Additional Information:

  • Item Code: KN-Pusher
  • Production Capacity: 5-10 Per week
  • Delivery Time: 2-3 Days depends on destination
  • Packaging Details: Single ETO Packed ready to use

View Complete details

Yes! I am Interested Request a call back

iPaque Microwave Ablation Generator

  • iPaque Microwave Ablation Generator
  • iPaque Microwave Ablation Generator
iPaque Microwave Ablation Generator
Get Best Quote
Rs 14,00,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Freq range2 GHz to 50 GHz
Output power-120 to +10 dBm
Phase noise-110 dBc/Hz
RF connectorSMA
ModulationPulse
PC interfaceUSB
Frequency3 mhz
Country of OriginMade in India
Microwave ablation (MWA) is a minimally invasive procedure that uses microwave energy to heat and destroy abnormal tissue, such as tumors. A small probe or antenna is inserted into the target area under image guidance (like ultrasound or CT), and microwave energy is emitted to raise the tissue's temperature to over 100°C100 degrees cap C100°��, killing the cells. It can be used to treat various tumors, including in the liver, and has advantages like faster heating, larger treatment areas, and the ability to ablate multiple tumors at once compared to older methods like radiofrequency ablation.

Applications
  • Liver cancer: Commonly used to treat early-stage liver cancers.
  • Breast tumors: Used for small, benign breast tumors (fibroadenomas). 
  • Other cancers: Can be used for other cancers where similar ablation techniques are used, such as in the lungs. 
Advantages
  • Faster and more efficient heating: Microwave energy heats tissue faster and more uniformly than other methods.
  • Larger treatment area: Can ablate larger tumors more effectively.
  • Less susceptible to the "heat sink" effect: The high heat generated is less affected by blood vessels that would normally cool the tissue, allowing for more complete destruction in some cases. 
  • Simultaneous treatment: Can be used to treat multiple tumors at once. 


Additional Information:

  • Production Capacity: 2-5 per month
  • Delivery Time: 4 -6 weeks

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES